IQC software for clinical laboratories

IQC for laboratories.
Clarity in every decision.

Levey-Jennings charts, Westgard rules and documented investigations. All the information, in the right place.

Your quality control, in one view.3 levels · active control
QualiChart: active control with three levels, a populated Levey-Jennings chart and a 1:3s violation Enlarge screen
Actual product screen · demonstration data · Cropped view; enlarge to see the full screen.

More than 1,400laboratories supported

28 yearsdedicated to quality control

Supporttechnical and scientific

The IQC in practice

From alert to investigation.

Scroll to explore

Three steps to follow the decision.

Continue page

01 / Active control

Deviation appears. You know where to look.

Compare three levels on the Levey-Jennings graph and see Westgard rule violations along with runs.

In this example: level 2 above +3 SD, with violation of the 1:3s rule.

Try for 30 days
Active glucose control with three levels, filled graph, 1:2s alert and 1:3s rejection
Active control · 30 runs in history · demonstration data · Cropped view; enlarge to see the full screen.

02 / Critical review

From violated rule to documented action.

Investigate nonconformity, select causes and record corrective action in run context.

Rule, cause, action and date gathered to accompany the decision.

Try for 30 days
Critical run analysis with 1:3s rule, cause selected and corrective action filled in
Completed critical analysis · demonstrative data · Cropped view; enlarge to see the full screen.

03 / AI Assistant

More context to investigate the issue.

Consult suggestions for causes and next steps following a run with a broken rule, within the critical analysis itself.

AI supports research. The assessment and decision rest with your team.

Try for 30 days
AI assistant in critical analysis with interpretation of the violation, hypothesis of causes and next steps
AI assistant · illustrative answer with demonstrative data · Cropped view; enlarge to see the full screen.

Beyond control runs

Quality goes through the entire routine.

Analytical sigma, qualitative and semi-quantitative controls, critical supplies, temperature and audits: see what else your team can follow in QualiChart.

See all features

Analytical sigma

Analytical performance in a single number.

QualiChart calculates the sigma of each level using the TEa registered for the analyte, the bias against the package insert target and the cumulative CV: σ = (TEa% − |bias%|) / CV%.

  • Sigma by level on the control panel
  • Monthly evolution by lot, with the 6σ threshold
  • Percentage TEa, absolute TEa or both, with the source
Feature details
Monthly glucose sigma evolution at three levels, with an 8% TEa and the 6σ threshold
Monthly sigma evolution · 8% TEa · demonstration data

Qualitative and semi-quantitative

Also for results that are not numbers.

Qualitative analytes are evaluated against the expected result. Semi-quantitative analytes, against an acceptable range on an ordered scale, such as Negative, Trace and 1+ to 4+.

  • Conforming or nonconforming before saving
  • Acceptable range per level on an ordered scale
  • Trend alert and chart on the scale
Feature details
Semi-quantitative urine strip glucose panel with range per level, trend alert and results on the scale
Urine strip · acceptable range, trend alert and results on the scale · demonstration data

Critical supplies

Every lot, from receipt to the runs in which it was used.

Reagents, calibrators and critical consumables follow their life cycle in the system: approved supplier, receipt, acceptance, use on controls and closure, always with the next step indicated.

  • Qualified suppliers and lot acceptance
  • Lot recorded automatically on every run
  • Incidents, traceability and 13 reports
Feature details
Lot record with stages and next step
Lot record · current stage and next step · demonstration data

Equipment and temperature

Caution continues outside the analyzer.

Track refrigerators and other equipment with defined limits, measurement history and records of who took each reading.

  • Graph with limits and out-of-range readings
  • Observations for recording occurrences and interventions
  • History by equipment, period and responsible
Feature details
History and graph of the RF-01 refrigerator with limits of 2 to 8 degrees, an excursion and later readings within the range
RF-01 Refrigerator · temperature history and excursion · demonstration data

Internal audits

See what's covered. And what needs action.

Evaluate the routine with checklists, gather evidence and track nonconformities in a report by category.

  • Results and scores by category
  • Non-conformities with audit observations
  • Action plan and PDF report export
Feature details
Completed internal audit report, with results by category and two documented nonconformities
Audit completed · results and nonconformities · demonstrative data

Explore QualiChart with your team.

Create your account and start your 30-day trial.

Start a 30-day free trial

A story built with laboratories.

Laboratories that have already used QualiChart.

  • São Francisco de Assis Hospital Foundation
  • PNCQ
  • INCS
  • Freeman Laboratory
  • Saretta Laboratory
  • Souza Assunção Laboratory
  • Bioanalysis
  • Villela Cuts
  • Good Samaritan Social Benefit
  • Unimed Juiz de Fora
  • Labmed

In a laboratory routine

From the people
who use it.

Laboratory
Paulo C. Azevedo

The system gave us an overview of control in all laboratory units, which gives us the possibility of anticipating problems through real-time data analysis.

Silvana PiresTechnical responsible for the Paulo C. Azevedo Laboratory report
Read the full testimonial

A plan for your needs

Monitoring makes the difference.

Compare all plans

Autonomy in routine

QualiChart Premium

IQC management with follow-up after implementation for your team to explore the tool.

Discover Premium

Scientific support

QualiChart PLUS

Premium features scientific advice to support interpretation and technical decisions.

Get to know PLUS

Applied teaching

QualiChart Edu

License for teachers and institutions teaching laboratory quality control.

Meet Edu

Applied knowledge

From reading to the bench.

Guides, articles and materials to work on quality control with your team.

A Biosoft solution. Discover our history.

IQC exercise graph: two control levels with increasing trend
To study with the team

Levey-Jennings Graph Interpretation Exercises

Explore Material

Does your team use spreadsheets today?

Fewer files to check. More context to decide.

Compare how investigation results, formulas, permissions, and records are maintained in a spreadsheet and a dedicated system.

  • Graphs and calculations along with control data
  • Investigation and actions on run history
  • Shared routine with per-user access
Compare QualiChart with Excel →

Let's clarify

Before choosing your IQC system.

See plans and conditions →
How much does it cost?

The price depends on the number of units and equipment, in addition to the plan and monitoring chosen. Therefore, prices are upon request. Request a proposal with the scope of your laboratory.

How does deployment work?

In the demonstration, we show the routine and data that you already use. The team combines the setup and training outlined in the plan. The schedule depends on this survey.

Can I exit the spreadsheet?

The system offers import of runs via CSV file. The team guides the format and evaluates the data available for the transition.

Compare with Spreadsheets Does
Integrate with my LIS or equipment?

Enter the manufacturer, model and export format. Compatibility needs to be assessed for your environment prior to hiring.

Understand integration
How is data processed?

Access to the system is via user account and HTTPS connection. The Privacy Policy describes data processing and the channels for exercising your rights under the LGPD. Ask the team for the data storage, backup, access and processing conditions applicable to your contract.

Security and privacy
Can I test before hiring?

Yes. You can create an account and evaluate the system for 30 days free of charge. You can also request a guided demonstration. The commercial proposal informs users, equipment, validity, billing and cancellation rules before contracting.

Start my 30-day trial

Your next step in quality control

Put QualiChart to the test. Free for 30 days.

Create your account and evaluate QualiChart in your laboratory. Do you prefer a guided introduction? Request a demo with our team.